Gas filters Volga-Gaz coupling, mesh, etc.

Gas mesh filters FS
- Gas mesh filters of the FS series are designed to purify non-aggressive gases and air from mechanical impurities (scale and dust). The use of filters increases the service life of reducing, shut-off, safety and measuring equipment. The filter element retains all technical characteristics at an ambient temperature not lower than -40 °C.
- Models: FS-25; FS-32; FS-40; FS-50; FG-50S; FG-50SU; FGS-50; FGS-80.
- Gas filters of the FG series are designed to purify gas from impurities of solid particles, dust, rust and are installed in front of measuring instruments, shut-off valves, gas burners of boilers and other gas-burning devices. High-quality gas purification makes it possible to increase the reliability of the devices, increase the maintenance time by reducing wear. The right choice of filters is one of the factors that make it possible to ensure reliable and safe operation of gas supply systems.
- Models: FG-1,6-50; FG-1,6-50V; FG-1,6-80; FG-1,6-80V; FG-16-50- (DPD); FG-16-50V-(DPD); FG-16-80- (DPD); FG-16-80V-(DPD); FG-16-100- (DPD); FG-16-100V-(DPD).
- Gas filters of the FGCR series are designed to purify non-aggressive gases and air from mechanical impurities and moisture, installed in gas control points and gas control installations indoors or outdoors. They are constructed according to a longitudinal straight-through scheme. The use of filters increases the service life of reducing, shut-off, safety and measuring equipment. The filter material — nylon thread - retains all technical characteristics at an ambient temperature not lower than -40 ° C.
- FGKR-32; FGKR-50; FGKR-80; FGKR-100; FGKR-150.
- Gas filters of the FG series (type FS) on legs are designed for cleaning non-aggressive gases and air from mechanical impurities (scale and dust). The use of filters increases the service life of reducing, shut-off, safety and measuring equipment. The filter element retains all technical characteristics at an ambient temperature not lower than -40 °C.
- Models: FG-32FS; FG-50FS; FG-80FS; FG-100FS; FG-150FS; FG-200FS.
- Designed for cleaning non-aggressive gases and air from mechanical impurities (scale and dust). The use of filters increases the service life of reducing, shut-off, safety and measuring equipment. The filter element, usually mesh (by special order, it can be made from a fibrous-porous copolymer of propylene), retains all technical characteristics at an ambient temperature of at least -40 ° C.
- Models: FG-80P, FG-100P, FG-150P, FG-200P - with direct gas outlet. FG-80U1, FG-100U1, FG-150U1, FG-200U1 - with angular right gas outlet. FG-80U2, FG-100U2, FG-150U2, FG-200U2 - with angular left gas outlet.
- Designed for cleaning non-aggressive gases and air from mechanical impurities and moisture, installed in gas control points and gas control installations indoors or outdoors. They are constructed according to a longitudinal straight-through scheme. The use of filters increases the service life of reducing, shut-off, safety and measuring equipment. The filter element retains all technical characteristics at an ambient temperature not lower than -40 °C.
- Models: FGM-150; FGM-200; FGM-250; FGM-300; FGM-400.
- Designed for installation on gas pipelines in front of shut-off valves of gas-burning devices of boilers, heat generators, infrared heaters and other gas-burning installations in order to purify gas from mechanical particles to increase the reliability and durability of the equipment. The use of filters significantly increases the service life of reducing, shut-off, safety and measuring equipment. The main purpose is to be used in housing and communal services systems in front of gas meters and in furnace rooms, where boilers and other thermal units of small unit capacity are installed.
- Models: FN 1/2-2.x; FN 3/4-2.x; FN 1-2.x; FN 1 1/2-2; FN 2-2; FN 1/2-6.x; FN 3/4-6.x; FN 1-6.x; FN 1 1/2-6; FN 2-6.
- Designed for installation on gas pipelines in front of shut-off valves of gas-burning devices of boilers, heat generators, infrared heaters and other gas-burning installations in order to purify gas from mechanical particles to increase the reliability and durability of the equipment. The use of filters significantly increases the service life of reducing, shut-off, safety and measuring equipment.
- Models: FN 1 1/2-2; FN 2-2; FN 2 1/2-2; FN 3-1; FN 4-1; FN 6-1; FN 8-1; FN 1 1/2-6; FN 2-6; FN 2 1/2-6; FN 3-6; FN 4-6; FN 6-6; FN 8-6; FN 10-6.1; FN 10-6.2; FN 12-6.1; FN 12-6.2.
All Volga-Gaz products
The group "New Technologies" offers for review the products of the plant Volga-Gaz: gas control units
About Volga-Gaz
Volga-Gas. Production of industrial gas equipment. All manufactured products undergo comprehensive quality control through various test methods.
-
RELEASE OF HYDRAULIC FRACTURING
Hydraulic fracturing-gas control points. They are used for additional gas purification from mechanical impurities, reducing the gas pressure after the gas distribution station and maintaining it at a given value with subsequent uninterrupted and trouble-free supply to consumers. -
QUALITY CONTROL
All manufactured products undergo comprehensive quality control through various test methods, according to the requirements of technical documentation, including X-ray and ultrasonic inspection of welds. -
advantages
Constant work on improving the technological efficiency of production, expanding the product range and ensuring decent quality of products.
NEW TECHNOLOGIES GROUP
For sales and support please contact
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Volga-Gaz products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89
Send your question now: